Tablet Core
- Inappropriate tablet shape (flat surfaces) Choose tablet design that eliminates flat surfaces
Process/Equipment
- Pan speed too low Increase pan speed
- Atomization air pressure too low Increase atomization air pressure
- Spray rate too high Decrease spray rate
- Spray guns too close to bed Increase gun-to-bed distance
- Insufficient drying Increase drying (through higher inlet temperature or higher inlet airflow rate)